HP XP External Storage Software User Manual

Page 179

Advertising
background image

Connecting HP 200 Storage Virtualization System as external
storage

When connecting an HP 200 Storage Virtualization System (SVS200) as the external array, you must
set the SVS200 port to a host group for Windows hosts (host mode 0C: Windows or host mode 2C:
Windows Extension).

Also, the SVS200 port attribute must be “target” (for an External Storage XP connection) or “RCU
target port” (for a Continuous Access XP connection).

NOTE:

If you are using microcode that does not support the SVS200, the SVS200 is recognized as an XP12000
Disk Array. To recognize the connected external array as the SVS200, use the microcode version that
supports the SVS200 (which is microcode version 50-07-0X-XX/XX or higher). If you used an earlier
microcode version that does not support the SVS200 to map the SVS200 volumes, delete the mapping
setting, and then change the microcode version to the one that supports the SVS200.

Path status and examples of recovery procedures (SVS200)

Table 24

shows examples of the recovery procedures when the path status is not normal. When the

path status is not normal, use

Troubleshooting External Storage XP

and this table to recover the path

status. If you cannot restore the path, contact your HP account support representative.

Table 24 Path status and examples of recovery procedures (SVS200)

Examples of Recovery
Procedure

Path Status

LUN Manager might have changed
the LU paths' settings.

External device setting changed

Check the LU paths' settings. If the
LU paths' settings changed, change
the settings back to the ones when
the volume was mapped. Or use
External Storage XP to perform the
Delete LU operation, and perform
the Add LU operation again.

LUN Security XP Extension might
have changed the volume's access
attribute.
Check the volume's access
attribute. If the volume is protected
by the access attribute, release the
protection.

The volume might have been set as
a pair volume for data copy.

Illegal request

Check if the volume is set as a pair
volume of Business Copy XP,
Continuous Access XP, Continuous
Access XP Journal, or some other

External Storage XP user guide for the XP12000, XP10000, SVS200