Changing the Option Settings of Storage System

The information for the storage system's option settings information is displayed if you select
Subsystem Option from the tree on the System Option window.

Figure 43 Option Settings List for the Storage System

Activities: Number of volumes in concurrent initial copy operations (1 to 512).

Activities (CU): Shows whether the CU-by-CU setting of concurrent initial copy operations will
be enabled or disabled.

Path Watch: Time for monitoring a blockade in the paths (2 to 45 seconds).

Path SIM Watch: Time for monitoring SIMs that are reported when paths are blocked (2 to
100 seconds).

To change the storage system option settings:

1.

Click the System Option tab, and then select Subsystem Option in the tree (see

“System Option

Window” (page 79)

).

2.

Right-click the list to display the menu, and select System Option to open the System Option
dialog box (see

“System Option Dialog Box” (page 111)

).

3.

On the System Option dialog box, change the storage system options.

When the System Option dialog box opens, the current settings are displayed.

4.

Click the Set button to close the System Option dialog box. The desired changes are displayed
in the preview list. To cancel the change(s), click the Cancel button.

5.

Verify the desired change(s) in the preview list.

To change the settings, right-click the preview list, click Modify, make the desired changes,
and close the dialog box. The preview list displays the updated information.

To omit the settings, right-click the preview list, and click Delete. The changes are cancelled.

To cancel all operations, select all the operations in the preview list, right-click, and click
the Delete command, or click the Cancel button. The changes are cancelled.

6.

To apply the settings, click Apply.

If an error occurs in the setting, an error code is displayed in the Error Code column in the
preview list. To display the error message, right-click on the list, display the menu, and click
Error Detail. After you check the error message, click the OK to close the error message. If
necessary, remove the cause of the error message.