Table 38 Error Code and Error Contents When Operating RAID Manager (continued)

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

Pair cannot be created because the larger number than the number that is able to
be specified for consistency group number is specified.

B990

If this error occurs even if you omit to specify the consistency group number, contact
HP technical support .

The Swap Resync operation, that is to resynchronize the differential data from P-VOL
to S-VOL after S-VOL is swapped for P-VOL, cannot be performed because the S-VOL
is not in PSUS or SSWS status.

B994

XP Continuous Access pair cannot be created because the RCU path setting for
Remote Web Console is invalid.

B998

The LDEV configuration for the DKC might have been changed while starting the
RAID Manager. Restart the RAID Manager.

B9BD

The source of the command device has run out. Set the command device to Off and
to On again from the LUN Manager.

B9C0

A request for Pairresync was received. However, the command was rejected because
the corresponding pair was not in the Suspend status.

C162

A request for Pairsplit-S was received. However, the command was rejected because
the status change of the S-VOL failed.

C184

A request for Pairsplit-S was received. However, the command was rejected because
the pair status was invalid.

C189

A request for Pairsplit-S was received. However, the command was rejected because
the corresponding volume was changing the status or the group included the pair
in process of status change.

C18A

The copy pair cannot be split because the S-VOL is in the process of status transition.

C194

A request for Pairsplit-r was received. However, the command was rejected because
the specified pair status was already PSUS or PSUE.

C195

Pair split cannot be executed because the group includes no pair that can be split.

C198

A request for Pairsplit-r was received. However, the command was rejected because
the corresponding volume was changing the status or the group included the pair
in process of status change.

C199

The status of XP Continuous Access pair or XP Continuous Access Asychronous pair
cannot be transited during the power-on processing for DKC.

C1BE

The command was rejected because the specified volume is used for P-VOL.

C211

The command was rejected because the specified volume is used for S-VOL.

C212

The command was rejected because RCU is not registered or the registered RCU
information is invalid.

C214

The command was rejected because an internal logical error has occurred.

C215

The command was rejected because the pair status is invalid.

C218

The command was rejected because the P-VOL status is not PSUS, PSUE, or PDUB.

C21A

The command was rejected because RCU is not registered or the registered RCU
information is invalid.

C21C

The command was rejected because the pair release is executed to the volume other
than P-VOL.

C22A

The command was rejected because the volume status is SMPL.

C22C

Troubleshooting When Using RAID Manager