The Initial copy response time is the response time required for multiple initial copy operations.
You can use the following formula to get the initial copy response time. To get the time, you should
use the following values: the initial copy pace, the maximum number of maximum initial copy
VOLs, the speed of the line between the MCU and RCU, and the number of lines.

Initial copy response time (ms) = (1[MB] / “Speed of line between MCU-RCU[MB/ms]

(*1)

”)

x (“initial copy pace”

(*2)

/ 15)

x (“max number of maximum initial copy VOLs

(*3)

” /

“Number of lines between MCU-RCU”

(*4)

)

(*1)

When you connect the MCU with the RCU using direct Fibre Channel connections, specify

0.17[MB/ms] in Speed of line between MCU-RCU.

(*2)

For initial copy pacein the formula above, see

Table 25 (page 90)

.

(*3)

For max number of maximum initial copy volumes, use the value set up per storage system (see

“Changing the Option Settings of Storage System” (page 110)

). The default is 64.

(*4)

Even if max number of maximum initial copy VOLs/ Number of lines between MCU-RCUis

larger than 16, specify max number of maximum initial copy VOLs/ Number of lines between
MCU-RCU
as 16.

Table 25 Initial Copy Pace for Calculating the Initial Copy Response Time

Perform Initial Copy and Update Copy at a Time

Perform Initial Copy Only

Operation

Initial Copy Pace Specified at the
Time of Pair Creation is 9 to 15

Initial Copy Pace Specified at the
Time of Pair Creation is 1 to 8

8

Initial copy pace specified at the
time of pair creation

Initial copy pace specified at the
time of pair creation

XP RAID
Manager

8

Initial copy pace specified at the
time of pair creation

Initial copy pace specified at the
time of pair creation

Remote Web
Console

Table 26 Example setting

Round Trip Time
Specified [ms]

Number of
Maximum Initial
Copy VOLs

Initial Copy Pace

Number of Lines
between
MCU/RCU

Line Speed
between
MCU/RCU
[MB/ms]

Round Trip Time
between
MCU/RCU [ms]

160

64

15

4

0.1

0

220

64

15

4

0.1

30

360

64

15

4

0.1

100

IMPORTANT:

For users who use the XP12000/XP10000 disk array: To set the following

parameters, use the System Option window.

Maximum Initial Copy Activity

Path Blockade Watch

To change the RCU options:

1.

Click the RCU Operation tab, and click the MCU&RCU display button.

2.

Select and right-click the desired RCU in the list, click RCU Operation, and click Change RCU
Option to open the RCU Option dialog box. See

“RCU Option Dialog Box” (page 88)

.

3.

On the RCU Option dialog box, change the RCU options as desired, and click Set to close
the RCU Option dialog box (or click Cancel to cancel the RCU option operation). The preview
list displays the requested change RCU option operation.

4.

Verify the requested operation(s) displayed in the preview list.

To change the change RCU option operation, select the operation from the preview list,
right-click, and click Modify. To remove the operation, select it, right-click, and click Delete.

90

Performing XP Continuous Access Configuration Operations