HP StorageWorks XP Remote Web Console Software User Manual

Page 164

Advertising
background image

Table 38 Error Code and Error Contents When Operating RAID Manager (continued)

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

The capacity of the volume is different from the capacity of the P-VOL.

The volume is initialized by XP Business Copy.

The S-VOL status is not PSUS or PSUE.

C3DB

XP Continuous Access Asynchronous program products is not installed in RCU.

CB11

TrueCopy for Mainframe, XP Continuous Access, and XP Continuous Access Journal
cannot be mixed in the consistency group.

CB12

The consistency group for the RCU cannot be deleted because the reversing operation
between P-VOL and S-VOL by Takeover command failed.

CB19

The consistency group for the RCU was abnormally terminated because the reversing
operation between P-VOL and S-VOL by Takeover command failed.

CB1A

No dummy volume can be created in the S-VOL.

CB1D

The RCU does not support XP Continuous Access.

CB1F

In referring to the function bit, the system information reference was abnormally
terminated.

CB20

In Pairresync, all difference setting was abnormally terminated.

CB21

(When connected to XP1024/XP128 Disk Array series) the port number and the
LUN exceed the range that can be set by the series.

CB5C

(When connected to XP1024/XP128 Disk Array series) the LUN and the device
number exceed the range that can be set by the series.

CB5D

When connected to the old model, LUSE pairs with different amounts of capacity
cannot be created.

CB5E

If the path is set between CUs, LUSE pairs with different CUs cannot be created.

CB5F

XP Continuous Access is not installed in the RCU.

CB60

One DKC cannot include both the pair using Escon and the pair using Fibre.

CB62

Paircreate cannot be executed because the P-VOL is the volume for an external
storage system.

CB6E

Paircreate cannot be executed because the S-VOL is the volume for an external
storage system

CB6F

Paircreate cannot be executed because the P-VOL is the migration volume for an
external storage system.

CB71

Paircreate cannot be executed because the S-VOL is the migration volume for an
external storage system.

CB73

The device is not recognized correctly.

CB75

Paircreate cannot be executed because the paths are specified per storage system.

CB76

The used capacity for Data Retention Utility program product on the RCU exceeds
the licence capacity.

CB77

Paircreate cannot be executed because the specified S-VOL is defined as the
command device.

CB78

A request for Paircreate was received. However, the command was rejected because
the specified S-VOL belongs to the different CLPR from the CLPR for the consistency
group that is already registered.

CB7E

164 Troubleshooting

Advertising
This manual is related to the following products: