HP StorageWorks XP Remote Web Console Software User Manual

Page 154

Advertising
background image

Table 35 Troubleshooting RCU Path Status Problems (continued)

Corrective Action

Description

Path Status

the RCU to delete the path. Add the
path/RCU using Edit Path or Add RCU.

Fibre: Make sure that you entered the
correct Controller ID, and that the Fibre
Channel topology settings of the MCU and
RCU ports are correct.

Make sure the correct MCU port is
configured as an initiator port and the

The specified port is not configured as an
initiator port, or this path already exists.

Invalid Port

correct RCU port is configured as an RCU
target port.

Make sure that you entered the correct RCU
S/N and SSID and path parameters (port,
link address, logical address).

Delete the failed path. You may need to
change the minimum paths setting or delete
the RCU to delete the path. Then add the
path/RCU using Edit Path or Add RCU.

Delete the failed path. Check the port
number or the cable connection, and retry.

The specified port number is invalid. The
cable is not connected to the specified port.

Port number
invalid

Install the microcode that supports the fibre
remote copy function on the RCU side.

The microcode on the RCU side does not
support the fibre remote copy function.

Fibre remote
copy is not
supported.

Delete the failed path and retry.

A timeout error has occurred between the
MCU and RCU.

Communication
error

Make sure that you entered the correct RCU
port number. Correct the port number if
necessary.

The specified port in the RCU is physically
disconnected from the MCU.

RCU Port
Number
Mismatch

Make sure that the MCU and RCU are
physically connected.

Make sure that the Fibre Channel topology
settings for the MCU and RCU ports are
correct.

Make sure that the RCU port is configured
as an RCU target port.

The specified RCU port is not configured as
an RCU target port.

RCU Port Type
Mismatch

Make sure that the RCU port and remote
copy connection hardware (cables and

The MCU connected to the RCU
successfully, but a logical communications
timeout occurred.

Communication
Failed

switches) are properly configured and
functioning.

Repair the port status on the MCU.

The MCU port does not work.

Logical Blockade

Repair the port status on the RCU. Then
delete the path with Edit Path or Delete

The RCU port does not work.

RCU, and add the path again with Edit Path
or Add RCU.

Repair the path relay equipment. Then
delete the path with Edit Path or Delete

The path relay equipment does not work.

RCU, and add the path again with Edit Path
or Add RCU.

Replace the broken cable. Then delete the
path with Edit Path or Delete RCU, and add
the path again with Edit Path or Add RCU.

The connection cable is physically broken.

154 Troubleshooting

Advertising