Error code and error contents – HP StorageWorks XP Remote Web Console Software User Manual

Page 158

Advertising
background image

To identify the error code using the log displayed on the RAID Manager window, follow the
procedure below. For more information, see the HP XP RAID Manager User's Guide.

1.

Find the error code from the logs displayed on the RAID Manager window.

Figure 57 (page 158)

shows an example of a log displayed on the RAID Manager window.

Figure 57 Example of a Log Displayed on RAID Manager Window

Error codes appear on the right of SSB=. The alphanumeric characters of last four digits on
the left of the comma (,) indicates SSB1 (for example, B9E1), and the alphanumeric characters
of last four digits on the right of the comma (,) indicates SSB2 (for example, B901).

2.

See

Table 38 (page 158)

to find the meaning of the error code.

For details about the error codes that are not described in

Table 38 (page 158)

, contact HP

technical support (see

“Calling HP Technical Support” (page 166)

).

Table 38 Error Code and Error Contents When Operating RAID Manager

Error Content

Error Code

(SSB2)

Error Code

(SSB1)

A request for XP Continuous Access Paircreate was received. However, the command
was rejected because the specified P-VOL belongs to the different CLPR from the
CLPR for the consistency group that is already registered.

4A96

B901

B90A

B90B

B912

D004

You cannot execute the following operations to the XP Continuous Access pair in
2DC configuration:

B927

Swap Suspend

Takeover

XP Continuous Access pair cannot be created because the Mirror ID is invalid.

B928

The command for the XP Continuous Access pair operation was rejected because
the online microcode replacement is in process.

B929

XP Continuous Access pair cannot be created because the specified volume is a
command device.

B92A

Pair cannot be created because XP Continuous Access is not installed.

B934

The S-VOL hide mode is not supported.

B935

The specified volume is P-VOL. The pair cannot be released because the P-VOL is
specified as an S-VOL.

B93B

The specified volume is S-VOL. The pair cannot be released because the S-VOL is
specified as an P-VOL.

B941

The command was rejected because the volume status is SMPL.

B945

The specified LU is not defined. The DKC configuration might have been changed.
Restart RAID Manager.

B952

The pair operation cannot be executed because the pair status is PSUS, PSUE, or
PDUB.

B97B

The command was rejected because the volume status is SMPL.

B97C

158

Troubleshooting

Advertising
This manual is related to the following products: