Pairsplit-r: Allows you to split (suspend) pairs.

Pairresync: Allows you to resynchronize pairs.

Change Pair Option: Allows you to change the pair options.

The availability of the commands (enabled/disabled) depends on the status of the LU(s) or
pair(s) selected in the list.

4.

Click the command for the desired operation, use the dialog box to perform the operation,
and close the dialog box. The preview list displays the requested operation(s).

5.

Verify the specified pair operation(s). Make changes as follows:

To change an operation, select the desired operation from the preview list, right-click,
click Modify, make the desired changes, and close the dialog box. The preview list
displays the updated information.

To omit one or more operations, select the operation(s) to be omitted from the preview
list, right-click, and click Delete. The operations are removed from the list. If all operations
are removed, the list returns to its original display.

To cancel all operations, select all the operations in the preview list, right-click, and click
the Delete command, or click the Cancel button. All operations are removed, and the list
returns to its original display.

6.

To start the operation(s), click the Apply button.

If an error occurs in the setting, an error code is displayed in the Error Code column in the
preview list. To display an error message, select one LU, right-click, and click Error Detail.
After you see the error message(s), click OK to close the error message.

XP Continuous Access Snapshot Function

The XP Continuous Access snapshot function writes the user-selected XP Continuous Access pair
status information to a text file on the SVP, which you can then download. The status information
reported in this file is determined by the selections on the Display Filter dialog box (see

“Display

Filter” (page 67)

). You can use this function to verify completion of your XP Continuous Access

operations.

You can use the snapshot function only while client file access is enabled. When client file access
is not enabled, the Export button (the button for the snapshot function) is not displayed on the Pair
Operation window. For the further information on the client file access settings, see the HP
XP24000/XP20000 Remote Web Console User's Guide
.

Table 30 (page 118)

describes the XP Continuous Access Snapshot function.

“Example of an XP

Continuous Access Snapshot File”

shows an example of an XP Continuous Access Snapshot file.

Table 30 Snapshot Function

Text (See the example shown below)

Data format

The XP Continuous Access pairs to be reported are determined by the selections on the
Display Filter dialog box.

Target data

When Subsystem or an LDKC is selected in the tree, you can stop the process by clicking
the Cancel button in the dialog box displayed during the execution of the Snapshot
function.

Termination

Each time the Export command is selected, the previous status data is deleted and the
new data is written.

Initialization

118

Performing XP Continuous Access Pair Operations