Deleting logical paths – HP XP Continuous Access Software User Manual

Page 154

Advertising
background image

Refresh: Refreshes the information in the DKC Status window.

Close: Closes the DKC Status window.

Table 34 Logical Path Status

Remarks

Status

This path has been successfully established and can be used for XP Continuous
Access Journal remote copy activities.

Normal

An operation for configuring or deleting this logical path is in progress.

Nothing

An error occurred with the initialization of a connection between the local and the
remote storage systems. The probable causes are:

Initialization Failed

No cable is connected to the local storage system.

No cable is connected to the remote storage system.

No cable is connected to the network device between the local and the remote
storage systems.

This indicates one of the following statuses:

Communication
Timeout

A timeout error has occurred between the primary and the secondary storage
systems.

A logic error was detected between the primary and the secondary storage
systems.

The local storage system rejected the function for configuring a logical path
connection. All logical path resources in the local storage system might be used
for other connections.

Resource Shortage
(Port)

The remote storage system rejected the function for configuring a logical path
connection. All logical path resources in the remote storage system might be used
for other connections.

Resource Shortage
(Pair-Port)

The serial number of the storage system connected to this logical path does not
match the serial number specified in theAdd DKC window.

Serial Number
Mismatch

The port is not an initiator port.

Invalid Port

This indicates one of the following statuses:

Pair-Port Number
Mismatch

The specified port number is incorrect.

The port in the remote storage system is physically disconnected from the local
storage system.

The port on the remote storage system is not an RCU target port.

Pair-Port Type
Mismatch

A communications timeout error has occurred on the path between the primary
and the secondary storage systems.

Communication Failed

Deleting Logical Paths

Before deleting the logical path(s), make sure that the remaining number of logical paths will be
greater than the minimum number of paths setting (see

“Changing Options for Logical Paths and

Storage Systems” (page 149)

). The delete path operation will fail if the number of remaining paths

is equal to or less than the minimum number of paths.

To delete the logical path(s), follow the described in this section. The primary storage system
administrator and the secondary storage system administrator can perform this operation.

1.

Ensure that the Remote Web Console main window is in Modify mode.

For detailed information about how to do this, see the HP XP24000/XP20000 Remote Web
Console User Guide
.

2.

Ensure that the DKC Operation window is open (see

“DKC Operation Window” (page 130)

).

154 Configuring Storage Systems and Logical Paths

Advertising
This manual is related to the following products: