HP XP Continuous Access Software User Manual

Page 235

Advertising
background image

Table 45 Error Codes and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code

(SSB2)

Error Code

(SSB1)

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the state of S-VOL was not
SMPL.

EB5E

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the program product of XP

EB5F

Continuous Access Journal was not installed in the secondary storage
system.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the volume capacity of
P-VOL was different from the volume capacity of S-VOL.

EB60

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the path between the
primary and the secondary storage systems was not valid.

EB61

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified P-VOL was
a command device.

EB62

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the restore journal group
was already linked with another journal group.

EB63

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity
exceeded the charging capacity of the program product.

EB64

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because of the abnormal end that
is related to the charging capacity of the program product.

EB65

The command was rejected and the retry processing was ordered because
P-VOL SUSPENDING was detected by executing the RAID Manager
horctakeover

(resync) command.

EB66

The XP Continuous Access Journal pair create processing was doubly
executed:

EB6C

There are no problems if the initial copy operation was restarted when
the primary storage system is powered off.

There are no problems if an XP Continuous Access Journal pair is
created when the primary storage system is reset.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the XP Continuous Access
Journal program product was not installed in the primary storage system.

EB6E

The XP Continuous Access Journal pair cannot be created because the
specified S-VOL is assigned to the copy pair of other program products.

EB70

The XP Continuous Access Journal pair cannot be created because the
specified S-VOL is the system disk.

EB73

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the journal cache of the
restore journal group remained.

EB7A

The XP Continuous Access Journal pair cannot be created because the
specified S-VOL is an external volume.

EB7D

Troubleshooting When Using RAID Manager 235