Table 45 Error Codes and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code

(SSB2)

Error Code

(SSB1)

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the path between the

E89A

storage devices for the both-way was not defined. Check whether the
bidirectional normal path was defined or not.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified master journal

E89B

group or the restore journal group remembered the state of connection
with another storage system in the past. Specify another journal group,
or delete the journal group once, then retry the registration again.

The specified journal group number is unregistered.

E8A6

Journal volume is unregistered on the specified journal group.

E8A7

A request of XP Continuous Access Journal suspend pair was received.
However, the command was rejected because the specified volume was

E8A8

not for an XP Continuous Access Journal pair or was a volume of another
journal group.

XP Continuous Access Journal copy pair cannot be suspended because
of the power-on processing.

E8A9

A request of XP Continuous Access Journal Paircreate (journal suspend
mode) was received. However, the command was rejected because the
mirror ID of the specified restore journal group was already used.

E8B6

A request of XP Continuous Access Journal Paircreate, Pairresync, or delta
resync operation was received. However, the command was rejected

E8F7

because there are multiple journal groups in the specified consistency
group.

A logic error occurred in the system, and the command was rejected.

E8FB

A request for XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified P-VOL was
already used as the S-VOL.

EA00

A request for XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified P-VOL was
already used by another XP Continuous Access Journal pair.

EA01

A request for XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified S-VOL was
already used as the P-VOL.

EA02

A request for XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the specified P-VOL was
already used by another XP Continuous Access Journal pair.

EA03

A request of XP Continuous Access Journal Paircreate was received.
However, the XP Continuous Access Journal pair cannot be created

EA07

because of XP Continuous Access Journal pair registrations in the primary
journal group exceeds the upper limit.

A request of XP Continuous Access Journal Paircreate was received.
However, the XP Continuous Access Journal pair cannot be created

EA08

because the number of XP Continuous Access Journal pair registrations
in the secondary journal group exceeds the upper limit.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the state of master journal
group was other than Initial, Active, or Stop.

EA09