HP XP Continuous Access Software User Manual

Page 232

Advertising
background image

Table 45 Error Codes and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code

(SSB2)

Error Code

(SSB1)

A request of XP Continuous Access Journal delete pair was received.
However, the command was rejected because the specified S-VOL was
in the state of Transition.

EA3A

A request of XP Continuous Access Journal suspend pair (Reverse mode)
was received. However, the command was rejected because the specified
S-VOL was in the state of Suspending.

EA3B

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EA40

exceeded the charging capacity of the primary storage system’s program
product.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EA41

exceeded the charging capacity of the secondary storage system’s
program product.

In the intermediate site in the cascading configuration combining three
XP Continuous Access Journal sites, a request of XP Continuous Access

EA42

Journal pair delete and suspend was received. However, since the journal
group status of the mirror combined with a mirror in the specified journal
group was Active, the command was rejected.

A request to delete or suspend an XP Continuous Access Journal pair was
received. However, the command was rejected because the specified

EA8B

volume is used in the system that consists of multiple primary and
secondary storage systems.

A request to create an XP Continuous Access Journal pair for the system
that consists of multiple primary and secondary storage systems was

EA92

received. However, the command was rejected because the microcode
was being replaced.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the volume specified for
the primary volume was being initialized by XP Business Copy.

EA95

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EAA1

exceeded the charging capacity of the primary storage system’s XP
Continuous Access Asynchronous. Check the license capacity as well as
the related program product.

In the configuration where three XP Continuous Access Journal sites are
combined, a request of XP Continuous Access Journal pair resync (journal

EA9D

resync mode) was received. However, since the specified journal group
did not exist, or no pair existed in the specified journal group, the
command was rejected.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EAA2

exceeded the charging capacity of the primary storage system’s XP
Continuous Access Journal. Check the license capacity as well as the
related program product.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EAA3

exceeded the charging capacity of the secondary storage system’s XP
Continuous Access. Check the license capacity as well as the related
program product.

A request of XP Continuous Access Journal Paircreate was received.
However, the command was rejected because the desired capacity

EAA4

exceeded the charging capacity of the secondary storage system’s XP

232 Troubleshooting