Table 9-1, Methods for controlling data compression – HP NonStop G-Series User Manual

Page 113

Advertising
background image

Managing Tape Drives

L700 (CTL700) Installation and User’s Guide 527338-004

9- 13

Controlling Data Compression

Using MEDIACOM to Set the Systemwide Compression
Default

MEDIACOM is the operator interface to the Distributed Systems Management
(DSM)/Tape Catalog.

The compression attribute of the ALTER MEDIADEFS command has two
possible settings: COMPRESSION IDRC and COMPRESSION OFF. The
default setting is COMPRESSION OFF. When COMPRESSION IDRC is
specified, compression mode is turned on for the 9840 tape drive.

To check and set the systemwide compression default specification:

1. Enter MEDIACOM at the TACL prompt:

-> MEDIACOM

MEDIACOM-T6028D42 (18DEC98)

MC>

2. Display the current system setting for compression:

MC> INFO MEDIADEFS

Support Level NOCATALOG

Automatic OFF

Compression OFF

MC>

Compression OFF means that by default, compression is not attempted
during a write to a scratch tape volume.

Table 9-1. Methods for Controlling Data Compression

Method

Description

MEDIACOM

The MEDIACOM ALTER MEDIADEFS command sets a
systemwide default.

The CLASS
TAPECATALOG
DEFINE command

The CLASS TAPECATALOG DEFINE can specify the
compression default for one job. (It overrides the current
systemwide default.)

The SETMODE 162
procedure call

The SETMODE 162 procedure call can specify the
compression mode for one write command. (It overrides
the current system wide default.)

Note. Only super-group users (user ID 255,n) can issue the ALTER MEDIADEFS command.