Figure 6-3, Extending the gripper – HP NonStop G-Series User Manual

Page 88

Advertising
background image

Operating the Tape Library

L700 (CTL700) Installation and User’s Guide 527338-004

6- 12

Moving the Robot

2. Push on the back of the reach mechanism until the gripper is extended to its full

position, as shown in

Figure 6-3

.

3. Hold the solenoid on top of the reach mechanism with one hand and grasp the

cartridge with the other. Rotate the solenoid switch clockwise until the cartridge is
released from the gripper, as shown in

Figure 6-4

on page 6-13.

Caution.

If the robot has been active, the solenoid and switch might be too hot to touch. Wait

for the solenoid to cool before touching it.

Figure 6-3. Extending the Gripper

Caution.

Check that the gripper mechanism is fully retracted. If it is left extended and the robot

is turned, the gripper mechanism will strike a storage cell. If it is left extended and the hand is
facing the tape library door when it is closed, the door will strike the gripper mechanism.