Configuring and Testing the Tape Library

L700 (CTL700) Installation and User’s Guide 527338-004

5- 18

Loading Tapes Into the Tape Library

12. Press SELECT.

13. At the “ARE YOU SURE?” prompt, confirm that the tape library is in Maintenance

Mode (offline) before beginning the test. Confirm by pressing the SELECT button.

14. After this diagnostic test runs to completion, press the MENU button to return to

the DIAGNOSTICS menu.

Running Other Diagnostic Tests

You might want to run all diagnostic tests. Descriptions of other test follow:

Loading Tapes Into the Tape Library

When diagnostic tests are completed, you can load the production tape cartridges
inside the tape library. The most efficient way to load a great quantity of tape cartridges
in the tape library is to manually load them into the array of cells.

Figure 5-4

on

page 5-19 illustrates this method.

Clean Drive

Mounts and dismounts a specified cleaning cartridge to a
tape drive.

Mount

Mounts a diagnostic tape cartridge to a selected tape drive.

Dismount

Dismounts a diagnostic tape cartridge to a selected tape
drive.

Demo Mode

Start a Get-Put Loop with customer cartridges simulate tape
library operation (See the Caution below).

Caution.

An audit update is required when the DEMO MODE completes. Perform an IPL of

the tape library to re audit it. Then notify the customer to update the host cartridge database.