Figure a-10 – HP NonStop G-Series User Manual

Page 128

Advertising
background image

Connecting the Fibre Channel Components for the
CTL700 Tape Library

L700 (CTL700) Installation and User’s Guide 527338-004

A -10

Powering on the CTL700 Tape Library and the Fibre

Channel Converter

Figure A-10. Location of the GBIC on the CT9800FC Fibre Channel Converter.

After you have installed the fiber cable, power on both the CTL700 tape library
and the CT9800FC Fibre Channel converter. The tape library must be powered
on first.

Powering on the CTL700 Tape Library and the Fibre Channel
Converter

1. Check that the power cords are fully seated into the AC power receptacles

on both the tape library and the Fibre Channel converter.

2. Attach the male end of the power cords to two separate power outlets.

3. Press the power switch to 1 “on position” on the CTL700 tape library.

4. Press the power switch to 1 “on position” on the CT9800FC Fibre Channel

converter.

5. Verify that both of the devices power on.

If connectivity is not established, the FC green LED will not be illuminated as
shown in

Figure A-11

on page A-11. You will need to check the fiber cable

connections on both the tape drive and the Fibre Channel converter.

Note.

Remember that the CTL700 tape library must be powered on first.

WARNING.

The CT9800FC Fibre Channel converter and the CTL700 tape library does not

have protection against lightning surges. For this reason, those customers located in high risk
areas should use external surge protection rated for use in their location and be able to handle
the power demand of the converter enclosure.