Creating a logical – HP OneView User Manual

Page 286

Advertising
background image

5.

Create the network set for the test networks:
a.

For Name, enter test networks and click Add networks.
The Add Networks to test networks dialog box opens.

b.

In the search box, enter test to filter the list of networks.

c.

Select all of the test networks listed and click Add.

d.

Select Untagged for the first network in the list of networks.

e.

Click Create.

The Network Sets screen opens. As shown in the following illustration, if you select a network
set in the

master pane

, the appliance displays details about that network set in the details

pane.

Network Sets

3

All labels

Create network set

Overview

test networks

General

Networks

Preferred bandwidth

2.5 Gb/s
10 Gb/s

none

Maximum bandwidth

Used by

test_1111

test_1114

Untagged

test_1112
test_1113

V

Reset

V

Actions

V

Name

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

prod networks

dev networks

test networks

4

V

1111

1112

1113

1114

A.5.4 Creating a logical interconnect group and its uplink sets

You can create logical interconnect groups, including their uplink sets, and their associated enclosure
groups in different ways:

You can create them before you add enclosures to the appliance.

You can create them during the enclosure add operation.

In the following procedures, you will define the groups before you add any enclosures. Choose
from:

“Creating a logical interconnect group for enclosure 1” (page 286)

“Creating a logical interconnect group for enclosure 2” (page 290)

A.5.4.1 Creating a logical interconnect group for enclosure 1

In this procedure, you will create a logical interconnect group for the first enclosure. It contains an
HP VC FlexFabric 10Gb/24-Port Module and an HP VC 8Gb 20–Port FC Module.

Creating the logical interconnect group

1.

From the

main menu

, select Logical Interconnect Groups and click + Create logical interconnect

group.
The Create logical interconnect group dialog box opens. The large boxes on the screen
represent enclosure interconnect bays, with bays 1 and 2 in the top row, bays 3 and 4 in the
next row, and so forth. Only interconnects of the same model can be installed in horizontally
adjacent bays.

2.

For Name, enter Enclosure1LIG.

286 Step by step: Configuring an example data center using HP OneView

Advertising