HP NetRAID-4M Controller User Manual

Page 139

Advertising
background image

6-33

Working with Container Attributes

In the example, the State column indicates container 0 is being used
as a Copy container in a

container reconfiguration

operation. (Note that the example eliminates some items in the

container list

display to make the example readable on this

page.)

HPN0> container list /full=TRUE

Executing: container list /full=TRUE

Cluster Num Total Oth Stripe Scsi Partition

Dr Partner Label Type Size Ctr Size Usage C:ID:L Offset:Size State

-- ------- ----- ------ ------ --- ----- ------ ------ ------------ ----

0 0 Volume 100MB None 2:01:0 Copy

Displaying the Reconfiguration Destination Container State

The

reconfiguration destination

container

state

attribute indicates that a container is being used as the destination
container, which is a hidden container used during a

container

reconfiguration

operation.

To display whether a container is the destination container in a

container reconfiguration

operation, use the

container

list

command with the

/full

switch, as in the following example.

In the example, the State column indicates Dest, which means that
container 62 (a hidden container) is being used as a destination
container in a

container reconfiguration

operation. (Note

that the example eliminates some items in the

container list

display to make the example readable on this page.)

HPN0> container list /full=TRUE

Executing: container list /full=TRUE

Cluster Num Total Oth Stripe Scsi Partition

Dr Partner Label Type Size Ctr Size Usage C:ID:L Offset:Size State

-- ------- ----- ------ ------ --- ------ ------ ------ ----------- ----

0 0 Reconf 100MB None

0 62 Stripe 100MB 32KB None 2:01:0 64.0KB: 100MB Dest

0 63 Volume 100MB None 2:01:0 64.0KB: 100MB Source

0 61 Stripe 1.00MB 32KB None 2:01:0 8.47GB:1.00MB Temp

Displaying the Reconfiguration RAID-5 Set Container State

The

reconfiguration RAID-5 set state

attribute indicates

that a container is being used as a RAID-5 set in a

container

reconfiguration

operation.

To display whether a container is being used as a RAID-5 set in a

reconfiguration

operation, use the

container list

command with the

/full

switch, as in the following example. In

Advertising