Displaying and enabling controller automatic spare – HP NetRAID-4M Controller User Manual

Page 41

Advertising
background image

3-17

Working with Controllers

Note:

The

pause_io

command is not available in the UNIX

environment.

To resume a controller’s I/O operations, use the

controller

resume_io

command, as in the following example. The

controller resume_io

command also rescans the SCSI channels

on the controller, verifying currently connected disks and
recognizing new disks that have been added to the channels.

HPN0> controller resume_io

Executing: controller resume_io

Displaying and Enabling Controller Automatic
Spare

A spare disk is a disk that you configure to automatically recover
data from a failed partition/disk in a redundant container. To assign
one or more spare disks for a single container, you use the

container set spare

command. To assign one or more spare

disks for all containers, you use the

container set

global_spare

command. Only mirror sets and RAID-5 sets use

the spare assignment if a disk fails. (Mirror sets and RAID-5 sets are
often referred to as redundant containers). The main characteristic of
these commands is that you must “manually” assign the spare disk
to one or more containers. In fact, you might consider the previously
described spare mechanism as “manually set spare”.

Note:

Automatic spare allows you to replace a failed disk

with a replacement disk. The controller automatically
assigns the disk you insert as a spare disk without your
having to first assign it manually using the

container

set spare

or c

ontainer set global_spare

command.

See Chapter 9, Modifying Containers, for more information on the

container

set

spare

and

container

set

global_spare

commands.

Advertising