Table 45. mrie methods – HP NetRAID-4M Controller User Manual

Page 72

Advertising
background image

4-22

Command Line Interface User’s Guide

Set the MRIE of your devices

To display the MRIE for a device, use the

disk show smart

command, as in the following example:

HPN0> disk show smart

Executing: disk show smart

Smart Method of Enable

Capable Informational Exception Performance Error

C:ID:L Device Exceptions(MRIE) Control Enabled Count

------ ------- ---------------- --------- ----------- ------

2:01:0 Y 0 Y N 0

2:02:0 Y 0 Y N 0

The Method of Informational Exceptions column indicates the
MRIE by showing one of the values shown in Table 4-5.

Table 4-5. MRIE Methods

In the example, the Method of Informational Exceptions column
shows the number 0 for the two devices; thus, the devices (2,1,0) and
(2,2,0) are set to not report exception conditions.

To set the S.M.A.R.T. MRIE, use the

disk set smart

command

with the

/mrie

switch, as in the following example. In the example,

the MRIE value is set to 6, report exceptions only when polled, on
device (2,1,0). See Table 4-5 for a list of methods that can be set.

HPN0> disk set smart /mrie=6 (2,1,0)

Executing: disk set smart /mrie=6 (CHANNEL=2,ID=1,LUN=0)

SMART parameters on disk (2,01,0) were successfully set.

Value

Meaning

0

Do not report exception conditions.

3

Report exceptions after a SCSI command
if reporting recovered errors

4

Unconditionally generate recovered errors

5

Generate no sense

6

Report exceptions only when polled