Displaying members of a diskset – HP NetRAID-4M Controller User Manual

Page 88

Advertising
background image

5-10

Command Line Interface User’s Guide

------ -------- ---------- ---------- ------ -------- -------

1 NO NO Saturn YES YES 5/26/2000-14:30:56

Displaying Members of a Diskset

The

members

attribute indicates the SCSI device ID for all disk

drives that reside in a diskset. You specify the disk drives that
initially reside in a diskset when you create a diskset using the

disk_set create

command. See Creating a Diskset on page 5-11

for information on creating a diskset. You add disks to a diskset
using the

disk_set add

command. See Adding a Disk to a Diskset

on page 5-12 for information on adding disks to a diskset. You
remove disks from a diskset using the

disk_set remove

command. See Removing a Disk from a Diskset on page 5-13 for
information on removing disks from a diskset. You can also delete
all disks from a diskset using the

disk_set delete

command. See

Deleting a Diskset on page 5-15 for information on deleting a diskset.

To display the SCSI device ID for all disk drives that reside in a
diskset, use the

disk_set list

command with the

/members

switch, as in the following example. In the example, the C:ID:L
column indicates that 2:00:0 is the only disk drive that resides on the
diskset.

HPN0> disk_set list /members

Executing: disk_set list

Diskset ID Creator ID Owner

------------------- ------------------ ------------------

0x01be868c1d74a640 0xfafaf001007a1c00 \\.\HPN0

Disks Attached OS Managed Label Shared Spare

------ -------- ---------- ---------- ------ -----

1 NO NO Saturn YES YES

Members of the Disk Set:

C:ID:L

-------

2:00:0

Advertising