Table 20 TSO Command Parameters

Command

Parameter

Value

Description

DEVN

Device number

PRIM

Primary volume

(S-VOL): SSID, serial

number, channel

connection address,

CU number. You can set

an additional parameter

for each request instead

of a serial number.
1. For an Add and

Split request (see section

Adding and Splitting

Pairs

” on page 82), the

parameter is MSF00.

This parameter is valid

for MODE(COPY) only.
2. For a Quick Resync

request, the parameter

is MRF00. This

parameter is valid for

MODE(RESYNC) only.
3. For a Quick Restore

request, the parameter

is MRQ00. This

parameter is valid for

MODE(RESYNC) only.
4. For a Reverse

Copy request, the

parameter is MRR00.

This parameter is valid

for MODE(RESYNC) only.

If you set a parameter

other than the parameters

listed at the left, the

command is rejected. CU

number or parameter is

valid only for the disk

controller emulation type

2105 or 2107

SEC

Secondary volume

(T-VOL): SSID, serial

number, channel

connection address,

CU number
COPY

NOCOPY

Whether you specify

COPY or NOCOPY for

the MODE parameter,

the storage system

recognizes it as COPY

mode. Therefore, initial

full-volume copy is

performed.

MODE

RESYNC

Re-establish a split or

suspended volume pair.

1

Copy speed is slow,

except when the disk

controller emulation

type is 2105 or 2107.

When the disk controller

emulation type is 2105 or

2107, the copy speed

is always medium

regardless what you

specify for the PACE

parameter.

PACE

Other than 1

Copy speed is medium.

CRIT

Not applicable.

Siz does not use this

parameter. Siz ignores it.

YES

MSGREQ function is

applicable.

MSGREQ

NO

MSGREQ function is not

applicable.

CESTPAIR

Hitachi ShadowImage for z/OS user guide

101

Advertising