Cautions on switching off power supply – HP StorageWorks XP Remote Web Console Software User Manual

Page 46

Advertising
background image

Status

Description

Host Status

S-VOL Access

T-VOL Access

Resync

When a split pair

is re-synchronized

in normal mode,

only the S-VOL

differential data

is copied to the

T-VOL. When a

suspended pair is

re-synchronized,

the entire S-VOL

is copied to the

T-VOL. No update

copy operations are

performed during

resync operation.

S-VOL = PPRI-PNDG

T-VOL = PSEC-

PNDG

Read/write

enabled

Read/write.

Read/write access

enabled for

HRX volumes.

Avoid read/write

operations.

Resync-R

When a split pair

is reverse copy, the

XP12000 storage

system copies

only the T-VOL

differential data

to the S-VOL. The

reverse copy cannot

be performed on

suspended pairs.

No update copy

operations are

performed during

reverse copy or

quick restore.

S-VOL = PPRI-PNDG

T-VOL = PSEC-

PNDG

Read/write-

disabled

Read/write.

Read/write access

enabled for

HRX volumes.

Avoid read/write

operations.

Suspend

The XP12000

storage system does

not perform update

copy operations to

a suspended T-VOL.

The XP12000

storage system

marks the entire

S-VOL track map as

differential data, so

the entire S-VOL is

copied to the T-VOL

when the pair is

resumed. Use

resync command

to resume a

suspended pair.

Reverse copy and

quick restore cannot

be used to resume

suspended pairs.

S-VOL = PPRI-SUSP

T-VOL = PSEC-SUSP

Read/write-

enabled

Read/write-

disabled.

Read/write access

enabled for

HRX volumes.

Avoid read/write

operations.

Cautions on Switching Off Power Supply

If you must switch off the power supply of the XP12000 storage system during Siz operations, make sure to:

Complete copying for the Siz pair in the SP-pend or V-split status to change the pair status from

SP-pend or V-split to split, and then switch off the power supply.

46

Overview of Hitachi ShadowImage for z/OS Operations

Advertising
This manual is related to the following products: