Table 23 – HP StorageWorks XP Remote Web Console Software User Manual

Page 105

Advertising
background image

Table 23

Parameter

Restriction

Error Report

PRIMARY

Siz does not use the PRIMARY

parameter within the SUSPEND

command.

MSGREQ

This parameter cannot be used for

ICKDSF when the volume specified

as the S-VOL or T-VOL is used for

TCz.
When the volume specified as

the S-VOL is used for TCz, check

the pair status by executing the

QUERY command to the T-VOL.
If you specify the volume which is

shared with TCz and URz M-VOL

(P-VOL) as Siz S-VOL, and if the

pair status of the TCz pair is

Duplex, the job of the ESTPAIR

command will end normally before

the copying processing of the

Siz pair completes even when

YES is specified for the MSGREQ

parameter.
When the volume specified as

the T-VOL is used for TCz, check

the pair status by executing the

QUERY command to the S-VOL.

QUIESCE

This parameter cannot be used

when the disk controller emulation

type is 2105 or 2107. To use this

parameter, set the disk controller

emulation type to 3990.
In case of TSO, Siz ignores this

parameter.

In case of ICKDSF, the job ends

abnormally (CC=12).

ONLINESEC

Online check is not available

when you perform backward

resynchronization by the ICKDSF

command. If you specify NO for

this parameter, or if you do not

specify the parameter, an error

occurs whether the volume is

online or offline.
Although no error occurs when

you specify YES for this parameter,

note that the copying operation

is performed without any online

check.

In case of ICKDSF, the job ends

abnormally (CC=12).

Set Path

Siz does not use the Set Path

parameter.