Fixing overplanting and underplanting in autoswath – Ag Leader Integra Users Manual User Manual
Page 176
160
Firmware Version 5.4
F
IXING
O
VERPLANTING
AND
U
NDERPLANTING
IN
A
UTO
S
WATH
AutoSwath Function — Turn Off Look Ahead
Problem — Underplanting
Recommended Action — Decrease look-ahead number
Result — The AutoSwath anticipates headlands later and turns the planter off later.
Problem — Overplanting
Recommended Action — Increase look-ahead number
Result — The AutoSwath anticipates headlands sooner and turns the planter off sooner.
AutoSwath Function — Turn On Look Ahead
Problem — Underplanting
Recommended Action — Increase look-ahead number
Result — The AutoSwath anticipates headlands sooner and turns the planter on sooner.
Problem — Overplanting
Recommended Action — Decrease look-ahead number
Result — The AutoSwath anticipates headlands later and turns the planter on later.