Firmware Version 5.4

• Fan Speed Calibration
The number of pulses that are generated by the sensor
during one revolution of the spinner dish. The default
setting is 4.

• PWM Gain
Determines how aggressively the control valve
responds when making spinner speed adjustments. The
higher the value the more aggressive the system
response is. The default setting is 20.

• PWM Frequency
The frequency that the PWM control valve is pulsed at.
Settings can be found from the manufacturer of the
valve. Typical settings range from 100-125 Hz. The

default setting is 100.

• Zero RPM Offset
Represents the maximum duty cycle that is sent to the control valve without producing any hydraulic flow
from the PWM valve. Using too high of a Zero RPM Offset value can cause the spinner system to not
properly shut off. The default setting is 30.

Note: See the PWM valve manufacturer information for recommended settings.

• Automatic Control

Checking this box enables closed loop spinner control.

Beginning with the 5.4 display firmware upgrade, checking the Automatic Control
check box exposes a Spinner Icon in the Task Bar that allows user to turn on/off
spinners from the Map Screen. Automatic Control default setting is unchecked.

C

REATING

P

RODUCTS

Creating application products including dry fertilizer blends can be completed upon initial setup or from
the Product Selection screen of the Field Operation Wizard when starting a field operation.

CREATING SINGLE PRODUCTS

To create a single product, to be added to a blend or to be applied by itself, use the on-screen wizard
described in the following steps.

Press: Home button > Setup (wrench) button > Configuration (tractor) button > Product tab > Add (+)
button > Application Product button

1. Select Product Type

Use drop-down menu to select Product Type.

Use drop-down menu to select Product.

Spreader Control

Channel 1

Channel 2

Channel 3

Spinner

Fan Speed
Calibration

PWM

Gain

PWM
Frequency

Zero RPM
Offset

Automatic
Control

4 pls/rev

20

100 Hz

30

Product