164

Firmware Version 5.4

H

YDRAULIC

S

EED

C

ONTROLLER

S

ETTINGS

FOR

S

PECIFIC

P

LANTERS

Note: The settings, provided below, should be a good starting point for controller settings. However, always
take the time to calibrate the seed meters, check for proper seed placement in the field, and make system
setting adjustments as needed. Do not rely solely upon the appearance of the On-Screen map. The on screen

map will not show gaps and overlaps caused by incorrect GPS Offsets or AutoSwath Look-Ahead settings.

Planter brand

Co

nt

ro

l V

a

lve

Co

nf

ig

ur

a

ti

o

n

PWM Fr

eq

ue

ncy

PWM

G

a

in

Zero F

low Of

fset

Gear Ratio

Pulses/R

ev

.

John Deere Planters

PWM

175

110

40

2.374 (chain)

2.417

(ProShaft)

360

White Planters

PWM

200

90

30

5.5

360

Case IH Planters

PWM

100

90

40

6.803

360