2. AT+CBST Select Bearer service type

AT+CBST

Select Bearer service type

Command Function

This command is used to select the bearer service with data rate and the connection
element to be used when data calls are originated.

Command Functional
Group

Call Control

Command Format Query
Response

AT+CBST=?
+CBST: (0-7, 12, 14, 65, 66, 68, 70, 71,75),
(0-1), (0-3)

Write Format
Response

AT+CBST=<baud rate>,<name>,<ce>
OK/ERROR

Read Format
Response

AT+CBST?
+CBST: 7,0,1

Execution Format
Response

N/A
N/A

Parameter Values

0

Autobauding (automatic selection of the speed; this setting is possible in case
of 3.1 kHz modem and non-transparent service)

1

300 bps (V.21)

2

1200 bps (V.22)

3

1200/75 bps (V.23)

4

2400 bps (V.22bis)

5

2400 bps (V.26ter)

6

4800 bps (V.32)

7

9600 bps (V.32)

12

9600 bps (V.34)

14

14400 bps (V.32)

65

300 bps (V.110)

66

1200 bps (V.110)

68

2400 bps (V.110 or X.31 flag stuffing)

70

4800 bps (V.110 or X.31 flag stuffing)

71

9600 bps (V.110 or X.31 flag stuffing)

<baud rate>

75

14400 bps (V.110 or X.31 flag stuffing)

<name>

0

none

0

transparent

1

non-transparent

2

both, transparent preferred

<ce>

3

both, non-transparent preferred

Example