Horner APG XLt OCS HE-GSM04 User Manual

Page 46

Advertising
background image

PAGE 46

GPRS / GSM MODEM Configuration

MAN4005-04-EN

operator <stat>, long and short alphanumeric format of the name of the operator,
and numeric format representation of the operator. Any of the formats may be
unavailable and will then be an empty field (,,). The list of operators comes in the
following order: Home network, networks referenced in SIM, and other networks.

Command Functional
Group

Network Information

Command Format Query
Response

AT+COPS=?
+COPS: (2, “ “, “ “, “31022”), (3, “ “, “ “, “310380”)
OK

Write Format
Response

AT+COPS=<mode>
[, <format> [, oper>]]

OK or
+CME ERROR: <err>

Read Format
Response

AT+COPS?
+COPS: 0
OK

Execution Format
Response

N/A
N/A

Parameter Values

0

automatic (<oper> field is ignored)

1

manual (<oper> field shall be present)

2

deregister from network

3

set only <format> (for read command +COPS?), do not attempt
registration/deregistration (<oper> field is ignored); this value is not applicable
in read command response

4

manual/automatic (<oper> field shall be present); if manual selection fails,
automatic mode (<mode=0) is entered

0

long format alphanumeric <oper>

1

short format alphanumeric <oper>

<format>

2

numeric <oper>; GSM Location Area Identification Number

<oper>

operator in format as in per <format>

0

Unknown

1

Available

2

Current

<stat>

3

Forbidden

Example:

To manually register the modem on a known PLMN:

To read operator information:


Page 46 of 62 ECN # 956

Advertising