Age1439_reference_clock, Nce_clock – Agilent Technologies VXI E1439 User Manual

Page 175

Advertising
background image

165

Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_reference_clock

Selects the source of the reference clock. This description also includes the query function:

age1439_reference_clock_get

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_reference_clock(ViSession id, ViInt16 refClock);
ViStatus age1439_reference_clock_get(ViSession
id, ViPInt16 refClockPtr);

Note

This command should be used only for specialized custom clock requirements. Most useful clock
setups can be supplied by

age1439_clock_setup

.

Parameters

id

is the VXI instrument session pointer returned by the age1439_init function.

refClock

AGE1439_FRONT_PANEL_CLOCK

specifies the front panel clock be used as the reference

clock. Use this in conjunction with

age1439_front_panel_clock_input

.

AGE1439_VXI_CLOCK

specifies that the VXI (rear panel) clock be used as the reference clock.

Use this in conjunction with

age1439_vxi_clock_output

.

refClockPtr

Returns a pointer to the current value of refClock.

Return Value

AGE1439_SUCCESS indicates that a function was successful.

Values other than AGE1439_SUCCESS indicate an error condition or other important status
condition. To determine the error message, pass the return value to

“age1439_error_message” on

page 102

.

See Also

“Default values” on page 201

,

“age1439_init” on page 132

,

“age1439_clock_setup” on page 78

,

“age1439_front_panel_clock_input” on page 131

,

“age1439_vxi_clock_output” on page 188

,

“age1439_reference_prescaler” on page 166

,

“Using clock and sync” in chapter 3