Agilent Technologies VXI E1439 User Manual

Page 195

Advertising
background image

185

Agilent E1439 Programmer's Reference

Functions listed alphabetically

AGE1439_GENERATE_OFF

disables triggering. This is useful in multi-module systems with the

same trigger type where you want only certain module(s) to generate a trigger.

genTrigPtr

points to the current value of the genTrig parameter.

magDwell

represents the number of samples that the signal magnitude must dwell low before begin
recognized as a low for the purpose of generating a magnitude trigger.

AGE1439_MAGDWELL_DEF

AGE1439_MAGDWELL_MAX

AGE1439_MAGDWELL_MIN

magDwellPtr

points to the current value of the magDwell parameter

magLevel

is used to set the triggering to detect when the envelope of a signal crosses the threshold while
using the magnitude trigger type.

AGE1439_MAG_LEVEL_MAX

sets the maximum allowable level and

AGE1439_MAG_

LEVEL_MIN

sets the minimum allowable level.

AGE1439_MAG_LEVEL_FS

sets the full scale magnitude trigger threshold.

AGE1439_MAG_LEVEL_DEF

sets the default magnitude trigger threshold.

The threshold is set to (

AGE1439_MAG_LEVEL_SCALE

× magLevel) dB relative to full scale

signal, where

−337 ≤magLevel ≤40.

Comment

Magnitude triggering is performed on the log magnitude of the signal. Magnitude triggering
occurs when the log magnitude of the signal crosses the specified magnitude trigger threshold.
Because of these facts magnitude trigger operation will not always be intuitive, and there is a case
that can be misinterpreted as improper operation:

Magnitude triggering may not occur when the magnitude trigger threshold level is set below the
known maximum amplitude of the input signal. The problem in such a case is that the trigger
threshold level is actually set too low, so that few, if any, signal samples fall below that level. A
transition from below the magnitude trigger threshold to above may never be detected if a sample
is not taken while the signal is below the trigger threshold. The solution is to INCREASE the
magnitude trigger level to the level at which there are frequent filter samples occurring both
above and below the magnitude trigger threshold

magLevelPtr

points to the current value of the magLevel parameter.

slope

selects the edge of the trigger source on which a trigger occurs for ADC and external triggers.

AGE1439_POSITIVE

sets triggering on the positive slope and

AGE1439_NEGATIVE

on the

negative slope.

slopePtr

points to the current value of the of the trigger slope parameter.

trigType

determines the trigger source.

AGE1439_ADC

generates a trigger based on the raw data samples from the ADC.

AGE1439_MAG

generates a trigger based on the log magnitude of the signal after it has been

filtered to a selectable bandwidth around the center frequency established by the age1439_
frequency_setup
function.

Advertising
This manual is related to the following products: