Initializing and closing, Analog setup, Data format – Agilent Technologies VXI E1439 User Manual

Page 71

Advertising
background image

61

Agilent E1439 Programmer's Reference

Functions listed by functional group

Initializing and closing

age1439_init

(on page 132)

−initializes the I/O driver for a module

age1439_close

(on page 86)

−closes the module's software connection

Analog setup

age1439_input_setup

(on page 141)

−sets all the analog input parameters

age1439_input_alias_filter

(on page 141)

−include/bypass the built-in analog anti-alias filter

age1439_input_alias_filter_get

(on page 141)

−gets the anti-alias filter state

age1439_input_autozero

(on page 141)

−nulls out the input dc offset in baseband mode

age1439_input_coupling

(on page 141)

−selects ac or dc input coupling

age1439_input_coupling_get

(on page 141)

−get the input coupling type

age1439_input_offset

(on page 135)

−sets the dc offset settings for the current range

age1439_input_offset_get

(on page 135)

−gets the dc offset settings

age1439_input_offset_save

(on page 136)

−saves the dc offset settings in NVRAM

age1439_input_range

(on page 141)

−sets the full scale input range

age1439_input_range_auto

(on page 137)

−performs auto-ranging

age1439_input_range_convert

(on page 138)

−converts input range to volts

age1439_input_range_get

(on page 141)

−gets the input range

age1439_input_signal_path

(on page 141)

−selects baseband or IF signal path

age1439_input_signal_path_get

(on page 141)

−gets the signal path state

age1439_input_signal

(on page 141)

−connect/disconnect the input signal to the input ampli-

fier

age1439_input_signal_get

(on page 141)

−gets the input buffer amplifier state

age1439_state_save

(on page 175)

−saves the current module state

age1439_state_recall

(on page 174)

−recalls a previous module state

Data format

age1439_data_setup

(on page 90)

−sets all format and data output flow parameters

age1439_data_blocksize

(on page 90)

−determines the size of the output data block

age1439_data_blocksize_get

(on page 90)

−gets the output data block size

age1439_data_delay

(on page 90)

−determines FIFO delay in continuous mode

age1439_data_delay_get

(on page 90)

−gets FIFO delay

age1439_data_memsize_get

(on page 88)

−returns module's memory size

age1439_data_mode

(on page 90)

−selects block mode or continuous mode

age1439_data_mode_get

(on page 90)

−gets the data mode

age1439_data_port

(on page 90)

−selects VME bus, local bus or fiber interface for output

transmission

age1439_data_port_get

(on page 90)

−gets the output port designation

age1439_data_resolution

(on page 90)

−selects 12 or 24 bits data resolution

age1439_data_resolution_get

(on page 90)

−gets the data resolution

age1439_data_scale_get

(on page 89)

−gets the data scale factor used to convert raw data to

volts

age1439_data_type

(on page 90)

−selects real or complex output data

age1439_data_type_get

(on page 90)

−gets output data type

age1439_data_spectral_order

−specifies the spectral order of the output data.

age1439_data_spectral_order_get

−gets the spectral order of the output data.

age1439_data_xfersize

(on page 96)

−allows a specified amount of data to be read before an

entire block has been acquired.

age1439_data_xfersize_get

(on page 96)

−gets the data transfer size

Advertising