Debugging, Digital processing, Fiber interface – Agilent Technologies VXI E1439 User Manual

Page 72

Advertising
background image

62

Agilent E1439 Programmer's Reference

Functions listed by functional group

age1439_lbus_mode

(on page 148)

−sets the transmission mode of the local bus

age1439_lbus_mode_get

(on page 148)

−gets the local bus transmission mode

age1439_lbus_reset

(on page 150)

−resets the local bus

age1439_lbus_reset_get

(on page 150)

−gets the local bus reset state

Debugging

age1439_cal_get

(on page 75)

−gets last calibration date of specified board

age1439_clock_recover

(on page 77)

−allows recovery from an out-of-spec external sample

clock

age1439_driver_debug_level

(on page 97)

−sets the debug level

age1439_driver_debug_level_get

(on page 97)

−gets the debug level

age1439_error_message

(on page 102)

−returns error information obtained from function

calls

age1439_error_query

(on page 103)

−queries the module for the most recent error

age1439_status_get

(on page 176)

−retrieves the module's status register information

age1439_meas_status_get

(on page 156)

- retrieves the current measurement status register

information

age1439_self_test

(on page 170)

−performs a self-test on the module and returns the result

Digital processing

age1439_combo_setup

(on page 87)

−a quick way to set blocksize, center frequency, and sig-

nal bandwidth with one function

age1439_filter_setup

(on page 120)

−sets the digital filter bandwidth and decimation filter

parameters

age1439_filter_bw

(on page 120)

−selects a signal filter bandwidth

age1439_filter_bw_get

(on page 120)

−gets the signal filter bandwidth

age1439_filter_decimate

(on page 120)

−enables/disables an extra factor of 2 decimation

age1439_filter_decimate_get

(on page 120)

−gets current state of extra decimation

age1439_filter_sync

(on page 123)

−synchronizes the decimation filter counter

age1439_frequency_setup

(on page 128)

−sets all zoom center frequency parameters

age1439_frequency_center

(on page 128)

−sets the center frequency

age1439_frequency_center_get

(on page 128)

−gets the current center frequency

age1439_frequency_center_raw

(on page 125)

−quickly sets the center frequency

age1439_frequency_center_raw_compute

(on page 127)

−quickly calculates the values for

age1439_frequency_center_raw

age1439_frequency_center_raw_get

(on page 125)

−gets the raw center frequency

age1439_frequency_cmplxdc

(on page 128)

−selects a complex baseband measurement

age1439_frequency_cmplxdc_get

(on page 128)

−gets the state of the baseband measurement

mode

age1439_frequency_sync

(on page 128)

−prepares the module for a synchronous frequency

change

age1439_frequency_sync_get

(on page 128)

−gets the state of the synchronous change mode

Fiber Interface

age1439_fiber_BOF

(on page 112)

−controls whether or not automatically generated

BOF events are transmitted

age1439_fiber_BOF_get

(on page 112)

−returns the current value of bofEnable

age1439_fiber_clear

(on page 106)

−clears all data from the fiber interface FIFO buffers

age1439_fiber_crc

(on page 112)

sets up the fiber interface to transmit and receive cyclic

Advertising
This manual is related to the following products: