Age1439_vxi_clock_output – Agilent Technologies VXI E1439 User Manual

Page 198

Advertising
background image

188

Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_vxi_clock_output

Selects which clock drives the VXI clock. This description also includes the query function:

age1439_vxi_clock_output_get

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_vxi_clock_output(ViSession id, ViInt16 vxiClock);
ViStatus age1439_vxi_clock_output_get(ViSession
id, ViPInt16 vxiClockPtr);

Note

This command should be used only for specialized custom clock requirements. Most useful clock
setups can be supplied by

age1439_clock_setup

.

Description

This function selects which clock the module should use to drive it’s VXI clock.

Parameters

id

is the VXI instrument session pointer returned by the age1439_init function.

vxiClock

AGE1439_FRONT_PANEL_CLOCK

specifies that the specified front panel clock drive the VXI

clock.

AGE1439_CLOCK_OFF

specifies not driving vxi clock on the backplane.

AGE1439_DIVIDED_ADC_CLOCK

specifies using the divided ADC clock to drive the vxi

clock.

vxiClockPtr

Returns a pointer to the current value of vxiClock.

Return Value

AGE1439_SUCCESS indicates that a function was successful.

Values other than AGE1439_SUCCESS indicate an error condition or other important status
condition. To determine the error message, pass the return value to

“age1439_error_message” on

page 102

.

See Also

“Default values” on page 201

,

“age1439_init” on page 132

,

“age1439_clock_setup” on page 78

,

“age1439_front_panel_clock_input” on page 131

,

“Using clock and sync” in chapter 3

Advertising
This manual is related to the following products: