Age1439_data_setup, Ze_get, Age1439 – Agilent Technologies VXI E1439 User Manual

Page 100

Advertising
background image

90

Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_data_setup

Sets all format and data output flow parameters. This description also includes information on the
following functions which set or query the format and flow parameters individually:

age1439_data_blocksize determines the size of the output data block.
age1439_data_blocksize_get gets the output data block size.
age1439_data_delay determines the FIFO delay in continuous mode.
age1439_data_delay_get gets the FIFO delay in continuous mode.
age1439_data_mode selects block mode or continuous mode.
age1439_data_mode_get gets the data mode.
age1439_data_port selects VME bus or local bus output port.
age1439_data_port_get gets the output port designation.
age1439_data_resolution selects 12 or 24 bits data resolution.
age1439_data_resolution_get gets the data resolution.
age1439_data_spectral_order specifies the spectral order of the output data.
age1439_data_spectral_order_get gets the spectral order of the output data.
age1439_data_type selects real or complex output data.
age1439_data_type_get gets output data type.

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_data_setup(ViSession id, ViInt16 dataType, ViInt16 resolution, ViInt16

mode, ViInt32 blocksize, ViInt32 dataDelay, ViInt16 spectralOrder, ViInt16 port);

ViStatus age1439_data_blocksize(ViSession id, ViInt32 blocksize);
ViStatus age1439_data_blocksize_get(ViSession
id, ViPint32 blocksizePtr);
ViStatus age1439_data_delay(ViSession
id, ViInt32 dataDelay);
ViStatus age1439_data_delay_get(ViSession
id, ViPInt32 dataDelayPtr);
ViStatus age1439_data_mode(ViSession
id, ViInt16 mode);
ViStatus age1439_data_mode_get(ViSession
id, ViPInt16 modePtr);
ViStatus age1439_data_port(ViSession
id, ViInt16 port);
ViStatus age1439_data_port_get(ViSession
id, ViPInt16 portPtr);
ViStatus age1439_data_resolution(ViSession
id, ViInt16 resolution);
ViStatus age1439_data_resolution_get(ViSession
id, ViPInt16 resolutionPtr);
ViStatus age1439_data_spectral_order(ViSession
id, ViInt16 spectralOrder);
ViStatus age1439_data_spectral_order_get(ViSession
id, ViPInt16 spectralOrderPtr);
ViStatus age1439_data_type(ViSession
id, ViInt16 dataType);
ViStatus age1439_data_type_get(ViSession
id, ViPInt16 dataTypePtr);

Description

Note

The functions, age1439_data_delay, age1439_data_mode, age1439_data_resolution, and
age1439_data_type work the same for the fiber interface as they do for the other interfaces.

Parameters

id

is the VXI instrument session pointer returned by the age1439_init function.

blocksize

determines the number of sample points in each output data block.

AGE1439_BLOCKSIZE_MIN

selects the minimum blocksize.

Advertising
This manual is related to the following products: