Microwave Leakage Test

Note before measuring:

• Make sure that the survey meter you are using

has been calibrated and is suitable for
measuring frequencies of 2,450 MHz.

• Do not exceed meter full scale deflection,

leakage meter should initially be set to the
highest scale, then adjusted down as necessary
to ensure that low readings are measured on the
most sensitive range.

• To prevent false readings, hold the probe on the

grip provided and move at 1” (2.5cm) / second.

• Always hold the probe at right angles to the

oven and point of measurement, ensuring the
probe is reading 2” (50mm) from the test area.

• With any casework removed the leakage should

not exceed 5mW/cm².


Procedure:
1.
Add 9oz/275ml of cold water into a 20oz/600ml

microwave safe container.

2. Place the 600ml container in the center of

oven and close the door.

3. Enter Service mode and select ‘Microwave leakage

test’ (A) from the oven tests.

4. Set the leakage meter to the appropriate scale/range.
5. Move the survey meter probe across all casework joins and vent areas

including those marked in yellow, shown opposite.

6. When the Magnetron circuit stops after 30 seconds, change the water

and re-select the test to continue.

7. Select the red ‘X’ on the display to stop the test at any time.
8. Readings must be below 5mW/cm². If a level greater than 5mW/cm² is

observed, this should be reported to Merrychef Service Department
immediately.

9. Notes should be kept of any leakage that is observed in terms of the level

and position on the oven. This information should be kept with the service
documentation.