Merrychef eikon e6 User Manual

Page 46

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

46

Error

Code

Oven Series

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

At oven start up
the QTS senses
that the AC mains
voltage read from
the SRB is out of
the ±10%

“SUPPLY
VOLTAGE (V)
OUT OF
RANGE"
message is
displayed on the

E089

E3, E4, E5

Recommission fail -
Cooling fan(s)

The cooling fan(s)
failed the
recommission test

Pressing the "Red
X" when
"CONFIRM
COOLING FAN IS
RUNNING" is
displayed

N/A

"E089
RECOMMISSIO
N FAIL
COOLING FAN"
message is
displayed in the

E2, E6

Pressing the "Red
X" when
"CONFIRM
COOLING FANS
ARE RUNNING" is
displayed

"E089
RECOMMISSIO
N FAIL
COOLING
FANS" message
is displayed in

E090

All

Recommission fail -
Convection fan

The convection
fan failed the
recommission test

Pressing the "Red
X" when
"CONFIRM
CONVECTION
FAN IS RUNNING"
is displayed

N/A

"E090
RECOMMISSIO
N FAIL
CONVECTION
FAN" message
is written to the

E091

E3

Recommission fail –
Turn Table

The turn table
failed the
recommission test

Pressing the "Red
X" when "OPEN
DOOR CONFIRM
TURNTABLE IS
ROTATING" is
displayed

N/A

"E091
RECOMMISSIO
N FAIL
TURNTABLE"
message is
written to the

E092

E2, E3, E4, E5

Recommission fail –
Convection Heater

The Convection
Heater failed the
recommission test

Pressing the "Red
X" when "HEATER
TEST IN
PROGRESS" is
displayed

N/A

"E092
RECOMMISSIO
N FAIL
HEATER"
message is
written to the

E6

Recommission fail –
High Convection
Heater

The high
convection heater
failed the
recommission test

Pressing the "Red
X" when "HIGH
HEATER TEST IN
PROGRESS" is
displayed

"E092
RECOMMISSIO
N FAIL HIGH
HEATER"
message is
written to the

E093

All

Recommission fail –
Magnetron(s)

The magnetron(s)
failed the
recommission test

Pressing the "Red
X" when
"MAGNETRON
TEST IN
PROGRESS" is
displayed

"E093
RECOMMISSIO
N FAIL
MAGNETRON"
message is
written to the

Advertising