Commissioning the oven – Merrychef eikon e6 User Manual

Page 61

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

61

COMMISSIONING THE OVEN

Initial Installation

1. Unpack the Oven and check for damage.
2. Check Oven Accessories.
3. Check location will provide adequate Ventilation.
4. Locate Oven onto a strong, level, non-flammable

Surface.

5. Remove panels & check all wiring and components

for security.

6. Refit panels.
7. Position the Oven with a minimum air gap of 2”

(50mm) sides & rear.

8. Check Electrical supply and connect.
9. Place a container of water in the oven and switch it

on.

10. Record Model version & check against serial plate.
11. Record QTS (UI) version.
12. Record SRB version.
13. Record Serial Number & check against serial plate.
14. Enter Service Mode.
15. Record Voltage & Frequency.
16. Record Magnetron Current Draw.
17. Check for Microwave leakage.
18. Record Heater current.
19. Check door opening on display.
20. Check filter removal on display.
21. Check fan speed.
22. Turn off the oven and remove the water.
23. Switch on oven and run up to temperature.
24. Operate Oven, Cooking a Standard Batch.
25. Supply User information & contact details to

Customer.

26. Instruct Users with an Overview of the equipment,

Operation & Safety (Hazards).

27. Complete Service Report.

After Service

Complete the following checks after the Oven has been
Serviced/Repaired/Tested before connecting to the
mains electricity power supply:

9

All internal electrical connections are correct

(see wiring diagrams).

9

All wiring insulation is correct and is not touching

any sharp edges.

9

All grounding connections are electrically and

mechanically secure.

9

All door safety interlocks are secure and

mechanically sound.

9

The door activates all of the door interlock

switches and in the correct order.

9

The door operation is smooth, and the arms run

freely in the slots.

9

The temperature sensor is correctly connected

to the SRB.

9

The casing is securely refitted with no trapped

wires.

9

Before finishing a service call, recheck the following
points:

9

Run the Recommission tests to ensure the oven

is functioning correctly and the touch screen is
working.

9

Microwave emissions are below permissible limit

of 5mW/cm².

9

The power output of the oven is checked in

accordance with the procedure.

9

The oven has correct 2” (50mm) air gap all

round and 2” (50mm) above. Air flow should not
be restricted.

9

Complete the Service Report.