Merrychef eikon e6 User Manual

Page 48

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

48

Error

Code

Oven Series

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

E102

E2, E3, E4, E5

Heater On

Convection
Heater element
failed to turn OFF
when requested

The current
measured by the
SRB is >1 amp
with the convection
heater OFF

Critical

"E102 HEATER
ON WITHOUT
REQUEST"
message is
written to the
error log.

E6

High Heater On

High Convection
Heater element
failed to turn OFF
when requested

The current
measured by the
SRB is >1 amp
with the high
heater OFF

Critical

"E102 HIGH
HEATER ON
WITHOUT
REQUEST"
message is
written to the

E103

All

Ambient overheat

The temperature
measured inside
the ovens cabinet
is too high

The ambient
temperature
measured by the
QTS and or SRB
is >70°C (158°F)

Warning

"E103 AMBIENT
OVERHEAT.
PLEASE
REMOVE,
CLEAN AND
REPLACE THE

E104

All

Overheat stats
released

The cavity
temperature is
above the high
limit

Cavity thermal
switch's (TCO)
have opened

Critical

"E104
OVERHEAT
STATS
RELEASED"
message is
written to the

The magnetron(s)
temperature is
above the high
limit and the
magnetron(s) are
off

Magnetron thermal
switch's (TCO)
have opened and
the Magnetron(s)
are off

E105

All

High or low freq

The frequency is
outside of the
ovens range of
operation

The SRB's line
monitoring circuit
detects that that
the frequency is
outside of the ±
2Hz range

Critical

"E105 SUPPLY
FREQUENCY
(Hz) OUT OF
RANGE"
message is
written to the

E106

All

Cavity overheat

Cavity
temperature is
higher than the
set point range
while cooking

The SRB has
detected that the
cavity temperature
is greater than
25°C (77°F) above
the setpoint the

Critical

"E106CAVITY
OVERHEATED"
message is
displayed in the
error log.

"E106CAVITY

E107

All

Comm error

There is no
communication
between the QTS
and the SRB

The QTS can no
longer send or
receive data from
the SRB.

Critical

“E107 COMM
ERROR"
message is
displayed on the
screen.

If h

bl i

The SRB no longer
receives data from
the QTS.

SRB writes error
to the log.

Advertising