E6 SERVICE MANUAL REV C 06/12

36

SW2

SW1

2

3

MAINS VOLTAGE COMPONENTS

Door Interlock Adjustment
Located on the door hinges are 3 safety interlock
microswitches, to prevent microwave emissions escaping
when the oven door is opened:

The Primary (SW3) breaks the electrical supply circuit to the
transformers.

The Secondary (SW2) breaks the microwave circuit if the

primary fails.

The Monitor switch (SW1) will short out the Microwave circuit
blowing the fuse if both Primary and Secondary interlocks fail.

IMPORTANT: In the event that the Monitor switch causes

the Microwave circuit fuse to blow, the Secondary (SW2)
and Monitor (SW1) microswitches must be replaced due
to exposure from high short-circuit currents.

The purpose of the following adjustment procedure is to set
the interlock to switch off the Microwave circuit when the door
is opened and for the Microwave circuit to operate when the
door is closed and the door seal expands.

Door Interlock Adjustment procedure:
9

Disconnect and isolate the oven from the electricity supply.

9

Allow the oven to cool down.

9

Remove the oven casing.

9

Ensure that the High Voltage Capacitors are discharged before

commencing work.

1 Place a red 2mm spacer over each top corner of the door seal

and carefully close the door.

2 On the left side slightly loosen the pivot screw.
3 Then slightly loosen the adjusting screws and pivot the

microswitch backplate downwards until the microswitch (SW3)
just clicks and tighten all the screws.

 

4 Open door to replace the red 2mm spacers with green 4mm

spacers and carefully close the door.

5 On the ride side, slightly loosen the pivot screw.

6 Then slightly loosen the adjusting screws and pivot the

microswitch backplate downwards until the microswitch (SW2)
just clicks and tighten all the screws.

7 Ensure that all the screws are tightened.
8 Remove spacers, then open and close the

oven door 5 – 10 times.

IMPORTANT: CHECK THE SWITCHES
OPERATE IN THE FOLLOWING SEQUENCE AS
MICROSWITCH SW3 MUST SWITCH THE
LOAD CURRENT.

Opening the door:

• SW3 opens first

• SW2

opens

second

• SW1 closes third

Closing the door:

• SW1 opens first

• SW2

closes

second

• SW3 closes third

1

4

5

6

SW1

SW2

SW3

2

3

OVEN DOOR OPEN

OVEN DOOR CLOSED

SW2

SW3

SW1

SW3

SW2

L1

L2

L2

SW1