Merrychef eikon e6 User Manual

Page 49

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

49

Error

Code

Oven Series

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

E108

All

QTS PM error

Wrong QTS PM
found / no QTS
PM found

The QTS has an
incorrect PM
(personality
module) installed
or no PM is
installed

Critical

“E108 QTS PM
FAILED"
message is
displayed on the
screen.

Thi

i

E109

All

SRB PM error

Wrong SRB PM
found / no SRB
PM found

The SRB has an
incorrect PM
(personality
module) installed
or no PM is
installed

Critical

“E109 SRB PM
FAILED"
message is
displayed on the
screen.

Thi

i

t

E110

All

Incompatible SRB
software version

SRB firmware
version is
incompatible with
the SRB

The SRB has
found that the
firmware running
the SRB is not
supported.

Critical

This error is not
recorded in the
error log.

"E110 SRB
VERSION
CONFLICT"

E3, E4, E5

SRB firmware
version is
incompatible with
the QTS version

The QTS has
found that the
firmware running
the SRB is not
supported.

E111

All

Cavity sensor error

The cavity
temperature
sensor is no
longer operating

The SRB is
reading an open or
shorted
thermocouple input

Critical

"E111 CAVITY
SENSOR"
message is
displayed in the
error log.

"E111 CAVITY

E112

E3, E4, E5

SRB board sensor
failed

The temperature
sensor on the
SRB board is no
longer operating

The SRB is
reading an open or
shorted sensor
mounted on the
board

Critical

"E112 CAVITY
SENSOR
CIRCUIT
FAILED"
message is
displayed in the

E2, E6

"E112 SRB
AMBIENT
SENSOR
CIRCUIT
FAILED"
message is

E113

All

Magnetron On without
request

Magnetron failed
to turn OFF

The magnetron
current measured
by the SRB was
outside of the
tolerance range

Critical

"E113
MAGNETRON
ON WITHOUT
REQUEST"
message is
written to the