Merrychef eikon e6 User Manual

Page 47

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

47

Error

Code

Oven Series

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

E094

E3, E4, E5

Recommission fail -
Filter in

The oven does
not sense that the
filter is installed

The SRB does not
see the magnetic
switch input from
the air filter while
the “INSTALL AIR
FILTER” message

N/A

"E094
RECOMMISSIO
N FAIL FILTER
INSTALL"
message is
written to the

E095

E3, E4, E5

Recommission fail -
Filter out

The oven does
not sense that the
filter has been
removed

The SRB does not
see the magnetic
switch input from
the air filter while
the “REMOVE AIR
FILTER” message

N/A

"E095
RECOMMISSIO
N FAIL FILTER
REMOVAL"
message is
written to the

E096

All

Recommission fail -
Door close

The oven door
switch has failed
the door close
test

The SRB does not
see the switch
input from the door
while the “CLOSE
OVEN DOOR”
message is

N/A

"E096
RECOMMISSIO
N FAIL DOOR
CLOSE"
message is
written to the

E097

All

Recommission fail -
Door open

The oven door
switch has failed
the door open test

The SRB does not
see the magnetic
switch input from
the air filter while
the “OPEN OVEN
DOOR” message

N/A

"E097
RECOMMISSIO
N FAIL DOOR
OPEN"
message is
written to the

E098

All

Incomplete Cleaning

The QTS has
determined that
the cleaning
process was
started but not
completed

Only tested for
when oven turns
on. The QTS has
found that during
the previous oven
on period, a

Warning

"E098
INCOMPLETE
CLEANING"
message is
displayed in the
error log.

E099

E3, E4, E5

Filter Override

User has removed
the filter and
elected to
continue cooking

User removes the
air filter. On the
screen where the
message “AIR
FILTER
REMOVED” and

Warning

"E099 FILTER
OVERRIDE"
message is
displayed in the
error log.

E100

All

Main power ON

The AC power to
the oven is
energized

The SRB is reset
after 25V AC
power is applied
from the
transformer

N/A

"E100 MAIN
POWER ON"
message is
written to the
ovens error log

E101

All

Magnetron failed

Magnetron failed
to turn On when
requested

The current
measured by the
SRB was outside
of the tolerance
range

Critical

"E101
MAGNETRON
FAILED"
message is
written to the
error log.