Merrychef eikon e6 User Manual

Page 55

Advertising
background image

E6 SERVICE MANUAL REV C 06/12

55

SRB Terminal Locations:

 

Connector 

Wire # Description 

X1-1 

14

Input, L1 from main terminal
block 

X1-2 

15

Input, L2 from main terminal
block 

X2-1 

16

Output, L1 to 24V control
transformer 

X2-2 

17

Output, L2 to 24V control
transformer 

X3-1 

64

Output, L1 to motor controller
(when activated) 

X3-2 

65

Output, L2 to motor controller

X4 

32

Input, L1 from main terminal
block (for high heater circuit)

X5 

10

Input, L1 from main terminal
block (for low and radiant heater
circuit) 

X6 

24

Input, L1 from primary door
switch (if door closed) (for
microwave circuit) 

X7 

13

Input, L2 from main terminal
block (for microwave circuit)

X8-1 

20

Input, L1 from secondary door
switch to connection block (if
door closed) 

X8-2 

22

Input, L2 from monitor door
switch to connection block (if
door open) 

X8-3 

23

Output, L1 to primary door
switch (if door closed), L2 (if
door open) 

X9-1 

58

Output, L1 to left cooling fan
(when activated) 

X9-2 

33

Output, L1 to right cooling fan
(when activated) 

X10 

Currently not used 

X11-1 

35

Output, L1 to right stirrer motor
(when activated) 

X11-2 

36

Output, L1 to right mag fan
(when activated) 

X11-3 

37

Output, L1 to left stirrer motor
(when activated) 

X11-4 

38

Output, L1 to left mag fan (when
activated) 

X12-1 

39

Output, L2 to right stirrer motor

X12-2 

40

Output, L2 to right mag fan

X12-3 

41

Output, L2 to left stirrer motor

X12-4 

42

Output, L2 to left mag fan

X13-1 

59

Output, L2 to left cooling fan

X13-2 

34

Output, L2 to right cooling fan

X13-3 

Currently not used 

X14 

blu

Output, L1 to high heater (when
activated) 

X15-1 

wht

Output, L1 to radiant heater
(when activated) 

X15-2 

yel

Output, L1 to low heater (when
activated) 