E6 SERVICE MANUAL REV C 06/12

51

Error

Code

Oven Series

Error/Event

Condition

Description

Trigger

Error

Level

System

Response

E6

Right Magnetron
overheat

The right
magnetron
thermal switch
has released but
the condition
clears in time

The right
magnetron thermal
cut-out has
released while the
right magnetron is
running and the

Warning

"E117 RIGHT
MAGNETRON
OVER
HEATED"
message is
written to the

The right
magnetron
thermal switch
has released but
the condition does
not clear in time

The right
magnetron thermal
cut-out has
released while the
right magnetron is
running and the

Critical

"E117 RIGHT
MAGNETRON
OVER
HEATED"
message is
displayed in the

E118

N/A

Bottom Convection
Fan failed

The bottom
convection fan
has failed

The feedback from
the bottom
convection fan
controller has
indicated to the
SRB that the

Critical

"E118 Bottom
CONVECTION
FAN
FEEDBACK"
message is
written to the

E119

E6

Low Heater On

Low convection
heater element
failed to turn Off
when requested

The current
measured by the
SRB is higher than
what is expected.
The calculation is
affected by the

Critical

"E119 LOW
HEATER ON
WITHOUT
REQUEST"
message is
written to the

E120

E6

Low Heater Off

Low convection
heater element
failed to turn On

The current
measured by the
SRB is lower than
what is expected.
The calculation is
affected by the

Critical

"E120 NO LOW
HEATER ON
REQUEST"
message is
written to the
error log.

E121

E2

Radiant On

Radiant heater
element failed to
turn Off when
requested

Not Implemented
Yet

Critical

"E121 RADIANT
ON WITHOUT
REQUEST"
message is
written to the
error log.

The current
measured by the
SRB is higher than
what is expected.
The calculation is
affected by the

E6