Command Reference

Beijer Electronics, MAEN993

15

Example 1
Set the backlight level of device at address 0.7 (group 0, address 7) to 130 (0x82):

Device at address 0.7 (group 0, address 7) has acknowledged the new backlight level
130 (0x82):

Example 2
Send an invalid “BRT” command to the device at address 0.7 (group 0, address 7).
The command has two data bytes, but “BRT” accepts only one byte:

Device at address 0.7 (group 0, address 7) has not accepted the command. Instead,
it sent a negative acknowledge with the current backlight level 128 (0x80). The
length of the response message exceeds the specified value 9, because of the invalid
data field length:

0

1

2

3

4

5

6

7

8

0x07

0x07

0x42

0x52

0x54

0x01

0x08

0x82

0x7D

0

1

2

3

4

5

6

7

8

0x06

0x07

0x42

0x52

0x54

0x01

0x09

0x82

0x7D

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x42

0x52

0x54

0x02

0x07

0xFF

0xFF

0x01

0

1

2

3

4

5

6

7...8

9

0x15

0x07

0x42

0x52

0x54

0x02

0xF9

0x82

0xFF

0x80