5.6.9 LAU_CONFIG_GETSTARTUPBRIGHTNESSMODE

(0x0124)

Startup Brightness Mode

The Beijer Electronics RBCs can be configured to start with different levels of bright-
ness. There are four modes for the backlight at startup:

• Backlight is off

• Backlight has the same level as before it was turned off

• Backlight starts with the default brightness, which can be configured as well

• Backlight is on with maximum brightness

Supported since Firmware Version
LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x24

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Device starts with minimum brightness (normally
backlight off)
0x01: Device starts with the same brightness as before it was
turned off
0x02: Device starts with default brightness
0x03: Device starts with maximum brightness

Type:

Byte

Length:

1

Description: Indicates at which level the backlight is set at startup