5.6.24LAU_CONTROL_RESET (0x0207)

Software Reset

This commands resets the software. All software initialization is done. This is not a
hardware reset or a power off/on. The parameter is for protection only. There must
be exactly this two bytes, or else it will answer with a negative acknowledge. This
command never returns a (positive) acknowledge; instead the reset is called.

Supported since Firmware Version

LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)
This command never returns a (positive) acknowledge.

Response Message (Negative Acknowledge)

Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.

Maximum Lr for this Command
10

Example
Reset the device at address 1.8 (group 1, address 8):

The device at address 1.8 (group 1, address 8) could not be reset:

0

1

2

3

4

5

6

7...10

11

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x02

0x07

Param ICHKD

Param

Value:

0xC6A5: This parameter is for protection purposes

Type:

Unsigned short

Length:

2

Description: Resets the software

0

1

2

3

4

5

6

7...8

9

0x15

ADR

0x4C

0x41

0x55

0x02

ICHKH

0x02

0x07

ICHKD

0

1

2

3

4

5

6

7...10

11

0x07

0x18

0x4C 0x41

0x55

0x04

0xFA

0x02 0x07 0xA5 0xC6 0x8B

0

1

2

3

4

5

6

7...8

9

0x15

0x18

0x4C

0x41

0x55

0x02

0xEE

0x02

0x07

0xF6

Advertising