5.6.22LAU_CONFIG_SETKEYPRESSMODE

(0x01AA)

Keypress Mode

The brightness of the Beijer Electronics RBCs can be configured adopt a determined
value if both dimmer keys are pressed for longer than one second. There are five key-
press modes:

• Backlight turns to darkest possible value (off )

• Backlight turns to the level of the last received SCOM BRT command

• Backlight turns to the default brightness, which can be configured as well

• Backlight turns to brightest possible value

• Backlight does not change

Supported since Firmware Version

LAUER RBC: 0.0.0.2

Command Stream

Note:

The changes made by this command will become active only after a restart of the de-

vice.

0

1

2

3

4

5

6

7...9

10

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x01 0xAA

Param ICHKD

Param

Value:

0x00: Set brightness to darkest possible value (off)
0x01: Set brightness to the value of the last received SCOM
BRT command
0x02: Set brightness to default brightness value
0x03: Set brightness to brightest possible value
0x04: Do not change brightness

Type:

Byte

Length:

1

Description: Set the keypress mode