5.6.28 LAU_STATUS_BUZZER (0x0306)

Current Buzzer State

Returns the current buzzer state. The buzzer state can be changed using the SCOM
command “LAU_CONTROL_BUZZER”.

Supported since Firmware Version

LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Example
Check whether the buzzer of the device at address 0.7 (group 0, address 7) is activat-
ed:

According to the data returned by the device at address 0.7 (group 0, address 7), the
buzzer is currently deactivated:

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x03

0x06

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Buzzer enabled
0x01: Buzzer disabled

Type:

Byte

Length:

1

Description: Current buzzer state