Command Reference

44

Beijer Electronics, MAEN993

5.6.17 LAU_CONFIG_SETREMOTECONTROL

(0x019C)

Remote Control Configuration

This command returns a configuration value that indicates whether the device is con-
figured to act as a remote controller. Beijer Electronics RBCs can be used as passive
devices, but can be additionally set up as remote controller devices to alter the back-
light level of any other device within the network every time the backlight is changed
by the buttons on the front of the device.

Supported since Firmware Version
LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Note:

The changes made by this command will become active only after a restart of the de-

vice.

0

1

2

3

4

5

6

7...9

10

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x01

0x9C

Param ICHKD

Param

Value:

0x00: Disable remote controlling capability
0x01: Enable remote controlling capability

Type:

Byte

Length:

1

Description: Decides if the device is used also as remote controller

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Remote controlling capability is disabled
0x01: Remote controlling capability is enabled

Type:

Byte

Length:

1

Description: Indicates whether the device is used also as remote controller